Fluorescence Correlation Spectroscopy

Reading molecular concentration and mobility from fluorescence fluctuations.

FCS records the tiny intensity fluctuations produced as fluorescent molecules diffuse in and out of a very small observation volume.

Correlating these fluctuations in time reveals how many molecules are present and how fast they move, with sensitivity down to single molecules. Where FLIM looks at nanosecond decays, FCS follows the same photons over microseconds to milliseconds.

FCS at a glance

Molecules diffusing through the focused observation volume make the fluorescence fluctuate: small molecules (A) quickly, large ones (B) slowly. Autocorrelating these fluctuations gives G(τ): larger molecules shift the curve to longer lag times, while the number of molecules sets its height. Schematic.

01 Principle

What is FCS?

A laser is focused to a diffraction-limited spot and kept at a fixed position. When a molecule enters this observation volume the fluorescence I(t) rises, and when it leaves it falls. How long a fluctuation lasts depends on how fast the molecule crosses the volume, and how large it is depends on how many molecules are present.

With only a few molecules in the volume at a time, each one entering or leaving changes the signal noticeably. FCS works best at low, nanomolar concentrations.

Fluorescence fluctuations in FCS

Figure 1 · Small molecules (A) cross the observation volume quickly and give fast fluctuations; large molecules (B) stay longer and give slow, broad ones.

02 Autocorrelation

The autocorrelation function

The intensity trace alone does not tell us how fast molecules move. To find out, FCS asks a simple question: how much does the signal still resemble itself after a short wait? The trace is copied, the copy is shifted in time by a lag time τ, and the two are compared. Repeating this for many values of τ builds the autocorrelation function G(τ).

01

At τ = 0

The signal is compared with itself. The match is perfect, so the correlation is at its maximum.

02

At short lag times

The molecules behind each fluctuation have not had time to leave, so the original and shifted traces still overlap strongly and the correlation stays high.

03

At longer lag times

The molecules have moved on, the overlap fades and the correlation decays.

Reading the curve

Decay time and amplitude

How quickly the correlation decays tells us how the molecules move. Small, fast molecules produce short fluctuations and lose correlation quickly. Larger or slower ones produce broader fluctuations, so the correlation lasts longer. The characteristic decay time of G(τ) is therefore related to the diffusion time τD, the average time a molecule takes to cross the observation volume.

Decay time

Diffusion time τD

Small, fast molecules lose correlation quickly; larger or slower ones keep it for longer, shifting the curve to longer lag times.

Amplitude

Number of molecules

G(τ) measures fluctuations relative to the average signal. If only a few molecules are present, one entering or leaving changes the signal a lot, so the fluctuations are large compared with the average and G(0) is high. If many molecules are present, one more or one less barely matters: the fluctuations average out and G(0) is low. In practice, G(0) is inversely proportional to the average number of molecules N in the volume.

An analogy

One person walking into a room with three people in it is easy to notice. One person walking into a full stadium goes unnoticed. FCS works the same way, which is why it is most sensitive at low, nanomolar concentrations.

Note

Lag time is not lifetime

Here τ is the correlation lag time, not the fluorescence lifetime used in FLIM. G(τ) is usually plotted on a logarithmic time axis and can be computed directly, through autocorrelation matrices or with Fourier-based methods, all based on the same principle.

Autocorrelation curves G(τ)

Figure 2 · Larger molecules shift the decay to longer lag times (higher τD). Fewer molecules in the volume give a higher amplitude G(0), more molecules a lower one.

03 Readout

What G(τ) reveals

Together, the amplitude and the shape of the curve report on how many molecules are present and how they move.

01

Concentration

The amplitude G(0) is inversely proportional to the average number of molecules N in the volume.

02

Diffusion and interactions

The diffusion time τD is the average time a molecule takes to cross the focus. Slower diffusion can mean a larger molecule, but also binding to a partner, incorporation into a complex, or confinement.

03

Multiple populations

Species with different mobility, or motion within a local “cage” followed by escape, add separate components to the curve, so it is read in the context of the experiment.

04

Photophysics

Fast components at short lag times report blinking processes such as triplet-state transitions.

04 Good practice

Measuring reliably

A few precautions make the difference between a curve that can be interpreted and one that cannot.

01

Know the volume

The observation volume has no sharp edges: it is set by the point spread function, which depends on the objective NA, the immersion medium and the wavelength. It can be estimated from these, or calibrated with a dye of known diffusion coefficient, to convert τD into diffusion coefficients and N into concentrations.

02

Keep concentrations low

Too many molecules make the fluctuations, and so the correlation amplitude, too small to measure.

03

Avoid photobleaching and saturation

Moderate excitation power keeps molecules from bleaching or saturating as they cross the focus.

05 Applications

What is FCS used for?

FCS turns fluctuations into numbers that describe concentration, size and mobility, in solution and in living samples.

01

Binding and complex formation

A molecule that binds a larger partner diffuses more slowly.

02

Concentration of fluorescent species

At low, nanomolar levels in solution or in cells.

03

Mobility in cells and membranes

Diffusion and confinement of proteins and probes in living samples.

04

Size and aggregation

Of particles, nanocarriers and aggregates in solution.

FCS and FLIM

FCS and FLIM use the same detected photons: their nanosecond timing gives the fluorescence lifetime, while their fluctuations over microseconds to milliseconds give FCS. A photon-resolved acquisition can therefore combine lifetime with diffusion and dynamics.

Read about TCSPC

Further reading

References

1Magde D, Elson E, Webb WW. Thermodynamic fluctuations in a reacting system – measurement by fluorescence correlation spectroscopy. Physical Review Letters. 1972;29(11):705–708.

2Lakowicz JR. Principles of Fluorescence Spectroscopy. 3rd ed. Springer; 2006. doi:10.1007/978-0-387-46312-4

3Yu L, Lei Y, Ma Y, et al. A comprehensive review of fluorescence correlation spectroscopy. Frontiers in Physics. 2021;9:644450.

From principle to measurement

FCS with FLIM LABS

Fast acquisition of fluorescence fluctuations, with the autocorrelation calculated directly and combinable with lifetime measurements.